Anti-pollution Composite Insulator

Anti-pollution Composite Insulator

EC Insulator Jiangxi Co., Ltd. manufactures anti-pollution composite insulators. These products are developed for overhead lines located in regions with persistent surface contaminants such as salt spray, dust and industrial pollutants. The insulator uses an ECR fiberglass epoxy core rod as its internal load-bearing structure, fully covered with HTV silicone rubber housing.
Send Inquiry

EC Insulator Jiangxi Co., Ltd. is one of the most reliable manufacturers and suppliers of anti-pollution composite insulator in China. With abundant experience, we are committed to offering high quality custom service. Please feel free to wholesale premium anti-pollution composite insulator made in China here from our factory.

 

Product Overview

 

EC Insulator Jiangxi Co., Ltd. manufactures anti-pollution composite insulators. These products are developed for overhead lines located in regions with persistent surface contaminants such as salt spray, dust and industrial pollutants. The insulator uses an ECR fiberglass epoxy core rod as its internal load-bearing structure, fully covered with HTV silicone rubber housing. Silicone rubber features excellent hydrophobicity. Even when the shed surface is covered by dirt, the surface conductivity stays low, which effectively prevents pollution flashover accidents.

We have delivered large quantities of such insulators for coastal projects, chemical plant surroundings and desert transmission routes. For these harsh environments, we usually extend the creepage distance and optimize shed profiles. The insulators can be used for newly-built overhead lines, as well as old lines that frequently trip under wet conditions. If customers provide field pollution survey data, we can adjust the design accordingly.

product-243-266

 

Key Features

 

An anti-pollution composite insulator consists of three core components: fiberglass core rod to bear mechanical tension, one-piece molded silicone rubber sheds covering the core, and metal end fittings assembled by hydraulic crimping.

The sheds are not simple round discs. We adjust their diameter and spacing to avoid water bridging between adjacent sheds. Once salt dust or ash accumulates on the surface, the hydrophobic property of silicone rubber can transfer to the contaminated layer. Water will form discrete droplets instead of continuous conductive films. This is the key reason why the insulators perform reliably in heavily polluted areas.

Compared with porcelain insulators, they are much lighter. This brings faster tower installation and lower transport cost. All metal fittings are hot-dip galvanized to resist corrosion under salty atmosphere for long-term service.

product-269-273

 

Technical Specifications

 

We keep standard anti-pollution models in stock for 33kV, 110kV and 220kV systems. The mechanical strength ranges from 70kN to 120kN, depending on string configuration and span length. They support 50Hz or 60Hz power frequency, with operating temperature range of -40°C ~ +70°C.

Creepage distance is not a fixed value in our catalog, which is the core characteristic of anti-pollution design. We define it according to the actual pollution class on site, normally Class III or Class IV. The core rod material is ECR fiberglass epoxy; sheds are HTV silicone rubber; end fittings are forged steel with hot-dip galvanization. Send us your voltage grade, pollution level and string type, and we will provide matching engineering drawings.

product-255-262

 

Application

 

Site condition evaluation is required before model selection. Coastal salt zones, steel mills, cement plants and dusty deserts all require different creepage settings. These insulators are widely applied on overhead transmission lines, suspension strings, tension strings and substation bus connections.

They are not necessary for all scenarios. For inland areas with clean air, standard composite insulators can meet requirements at a more competitive price. The anti-pollution type is worth extra investment only when the line suffers frequent flashover under fog or rainy weather.

product-303-309

 

Construction/Design

 

The fiberglass core rod undertakes all tensile load. Silicone rubber housing is integrally injection molded, leaving no gaps between core rod and rubber where water could penetrate. End fittings are connected via hydraulic crimping rather than adhesive bonding, ensuring stable joint performance for decades.

All metal components are hot-dip galvanized. Overall length and fitting dimensions comply with IEC overhead line hardware standards. They can be mounted on standard tower hardware without custom brackets. This advantage matters a lot for retrofit projects where clients do not want to replace the whole string. EC Insulator Jiangxi Co., Ltd. controls the full production process under unified quality management.

product-202-221

 

Standards & Testing

 

Our anti-pollution composite insulators comply with IEC 61109 and IEC 62217. Each batch undergoes tests including mechanical failing load test, power frequency withstand test, lightning impulse test, hydrophobicity assessment, tracking & erosion test and salt fog ageing test. We also inspect galvanizing thickness of metal fittings.

Factory test reports are supplied with every shipment. If tender documents require third-party witness test reports, we can arrange accordingly, though this will extend lead time by several weeks. Please inform us in advance for production planning.

product-240-240

 

Optional Configurations/Customization

 

Working conditions vary from project to project, so we offer flexible options. Creepage distance can be adjusted for pollution class II, III or IV. End fittings support ball-and-socket, clevis or tongue types to match existing tower hardware.

For 110kV and 220kV products, grading rings are often equipped to optimize electric field distribution near end fittings. Anti-bird sheds are available for bird-active regions. For heavy ice areas in winter, we can redesign shed profiles. DC versions for HVDC transmission lines are also available upon technical review by our engineering team.

product-213-213

 

Packaging & Delivery

 

For sea shipment, ISPM-15 wooden crates are adopted. Each insulator is wrapped with PE film inside the crate to prevent scratches on silicone sheds and friction damage to metal fittings. Matching hardware can be packed together in the same crate if ordered.

Every insulator is marked with voltage grade, mechanical load and batch number for full traceability. For full container orders, lead time is about 25 to 35 days after deposit receipt. Samples can be shipped within 7 to 12 working days.

product-209-243

 

FAQ - Anti-pollution Composite Insulator Frequently Asked Questions

 

9.1 Basic Concepts

Q: What makes an anti-pollution composite insulator different from a regular one?

A: They are both composite insulators with silicone rubber. The anti-pollution one is designed for dirty sites. It has a longer creepage distance and a shed shape that resists wetting better. Regular composite insulators are fine for clean inland areas, but they will not handle heavy salt or industrial grime the same way.

Q: How does hydrophobic migration actually help?

A: Silicone rubber naturally repels water. When a layer of salt dust or industrial dirt lands on top, that water-repellent property slowly moves into the dirt layer too. So instead of forming a wet film that conducts electricity, water sits as droplets. Leakage current stays low, and flashover becomes much less likely.

 

9.2 Technical Performance

Q: Does this mean no maintenance at all?

A: No. It cuts down cleaning visits a lot, but someone still needs to walk the line and look at the sheds. If a shed cracks, or the surface gets badly eroded after years, that unit should be replaced.

Q: How long do they last?

A: In normal heavy-pollution service, you can plan on 20 to 25 years. That number moves around a bit depending on how bad the pollution is, how well they were installed, and whether the line gets inspected regularly.

 

9.3 Installation and Maintenance

Q: Do I need special hardware to install them?

A: Usually no. Dimensions follow IEC standards, so they should fit your existing tower fittings. If your tower uses a non-standard fitting, just send us a drawing and we will match it.

Q: Do I have to test for zero value like porcelain insulators?

A: Not really. Composite insulators do not have the same "zero value" problem. Maintenance is mostly visual - look for shed damage, aging, or rust on the fittings.

 

9.4 Standard Compliance

Q: Which standards do you follow?

A: EC Insulator Jiangxi Co., Ltd. builds to IEC 61109 and IEC 62217. We also run salt fog ageing tests specific to the anti-pollution range. If your project has a local grid standard in the tender, send it over and we will check whether our design lines up.

 

Hot Tags: anti-pollution composite insulator, China anti-pollution composite insulator manufacturers, suppliers, factory, Anti pollution Composite Insulator, High Voltage Composite Insulator, polymer insulator, Rod Polymer Insulator, Silicone Rubber Insulator, Transmission Line Insulator