EC Insulator Jiangxi Co., Ltd. is one of the most reliable manufacturers and suppliers of metal oxide intermediate class surge arrester in China. With abundant experience, we are committed to offering high quality custom service. Please feel free to wholesale premium metal oxide intermediate class surge arrester made in China here from our factory.
Product Overview
The 21 kV Metal Oxide Intermediate Class Surge Arrester is designed to protect medium-voltage electrical systems and connected equipment against lightning and switching overvoltages. It uses zinc oxide (ZnO) varistor elements with nonlinear voltage-current characteristics to limit transient overvoltages and conduct surge current to ground.
With a rated voltage of 21 kV, a maximum continuous operating voltage (MCOV) of 17 kV, and a nominal discharge current of 10 kA, this arrester provides an intermediate-class protection configuration for power distribution and substation applications.
The silicone rubber housing provides external insulation through a shed-type structure. Its mounting base and four-point upper terminal arrangement support installation and electrical connection according to the specified mounting dimensions.
Electrical Specifications
The following table presents the main electrical and structural specifications of the 21 kV Metal Oxide Intermediate Class Surge Arrester.
| Parameter | Specification |
|---|---|
| Product Type | Metal Oxide Surge Arrester |
| Arrester Class | Intermediate Class |
| Rated Voltage (Ur) | 21 kV |
| Maximum Continuous Operating Voltage (MCOV / Uc) | 17 kV |
| Nominal Discharge Current (In) | 10 kA |
| Housing Material | Silicone Rubber |
| Protection Element | Zinc Oxide (ZnO) Varistor |
| Partial Discharge | ≤10 pC |
| Creepage Distance | 39.37 in (1,000 mm) |
| Dry Arcing Distance | 14.57 in (370 mm) |
| Applicable Standard | IEEE C62.11 |
Electrical Protection and Selection
The 21 kV rated voltage and 17 kV MCOV define the main voltage configuration of this arrester. The 10 kA nominal discharge current identifies its rated discharge-current class.
For project selection, the arrester ratings must be checked against:
- System nominal and maximum operating voltage
- System grounding arrangement
- Temporary overvoltage (TOV) conditions
- Protected equipment insulation level
- Required lightning and switching impulse protection levels
Residual voltage and energy withstand characteristics should be evaluated using the applicable product technical data and test documentation for the selected configuration.
Silicone Rubber Housing and Structural Design
Silicone Rubber External Insulation
The arrester uses a silicone rubber housing with alternating large and small sheds. The external insulation structure provides the required creepage path and supports outdoor installation.
| Structural Parameter | Dimension |
|---|---|
| Overall Height | 19.37 in (492 mm) |
| Structure Height | 13.78 in (350 mm) |
| Large Shed Diameter | 4.80 in (122 mm) |
| Small Shed Diameter | 3.62 in (92 mm) |
| Housing Inner Diameter | 2.13 in (54 mm) |
| Housing External Diameter | 2.36 in (60 mm) |
| Creepage Distance | 39.37 in (1,000 mm) |
| Dry Arcing Distance | 14.57 in (370 mm) |
Terminal and Mounting Configuration
The upper terminal assembly has four M12 threaded connection points arranged in a 2 × 2 pattern.
| Mounting Parameter | Specification |
|---|---|
| Upper Terminal Threads | M12 × 4 |
| Horizontal Bolt Spacing | 1.75 in (44.45 mm) |
| Vertical Bolt Spacing | 1.75 in (44.45 mm) |
| Lower Mounting Arrangement | Three-point mounting base |
Mounting plates, NEMA brackets, and compatible connection accessories can be arranged according to the selected installation configuration.
Buyers should check the complete mounting drawing, including the base bolt pattern and terminal interfaces, before finalizing installation dimensions.
Applications and Equipment Protection
The Metal Oxide Intermediate Class Surge Arrester is intended for overvoltage protection in medium-voltage power distribution and substation installations.
Typical application areas include:
- Power Distribution Systems: Protection of distribution equipment against lightning and switching surges.
- Substations: Surge protection for electrical equipment connected to medium-voltage networks.
- Power Transformers: Limiting transient overvoltages at transformer connections when arrester ratings and insulation coordination are suitable.
- Switchgear Installations: Protection of connected electrical equipment against transient overvoltage conditions.
The final arrester selection must account for system voltage, grounding conditions, temporary overvoltage exposure, and the insulation coordination requirements of the protected equipment.
Manufacturing, Testing and Quality Control
The arrester uses ZnO varistor elements as its core overvoltage protection components and silicone rubber as its external insulation material.
EC Insulator Jiangxi Co., Ltd. is a manufacturer of high-voltage electrical products and integrates product development, manufacturing, and testing. Its manufacturing capabilities include MOV forming, HTV compounding, and HTV compression molding.
Relevant electrical inspection and testing capabilities include:
- Reference voltage measurement
- Leakage current testing
- Residual voltage testing
- Partial discharge testing
- Power-frequency withstand testing
- Lightning impulse testing
These tests support electrical performance evaluation and manufacturing quality control. Applicable inspection items and acceptance criteria are determined by the product specification and order requirements.
Technical documentation can be arranged according to the order, including product specifications, inspection records, routine test reports, and applicable type test documentation.
Customization and Supply Options
Product configuration and supply arrangements can be coordinated according to the approved technical requirements and installation drawings.
| Item | Configuration |
|---|---|
| Rated Voltage | 21 kV configuration |
| Continuous Operating Voltage | 17 kV MCOV |
| Nominal Discharge Current | 10 kA |
| Housing Material | Silicone Rubber |
| Terminal Connection | Four M12 threaded connection points |
| Mounting Accessories | Mounting plates and NEMA brackets |
| Disconnector | Available for compatible configurations |
| OEM Surge Arrester Production | According to approved technical drawings and specifications |
| Product Identification | According to agreed order requirements |
For OEM and project orders, buyers can submit electrical specifications, installation drawings, terminal requirements, and accessory lists for technical review before production.
Packaging and Bulk Supply
Surge arresters can be packed in cartons, on pallets, or in wooden boxes according to product dimensions, order quantity, and transportation requirements.
For bulk procurement, order arrangements can cover:
- Product model and electrical ratings
- Mounting accessories and connection components
- Quantity and packaging configuration
- Product identification and shipping marks
- Delivery destination and shipping arrangements
EC Insulator Jiangxi Co., Ltd. operates manufacturing bases in Jiangxi, China, and Busan, South Korea, with integrated R&D, production, and testing capabilities for high-voltage electrical products.
Frequently Asked Questions
What are the rated voltage and MCOV of this Intermediate Class Surge Arrester?
The rated voltage is 21 kV, and the maximum continuous operating voltage (MCOV) is 17 kV. Both values should be checked against the maximum system voltage and grounding conditions.
What is the nominal discharge current?
The nominal discharge current is 10 kA. The required arrester class and discharge-current rating should be evaluated against the system protection design.
What material is used for the arrester housing?
The external housing is made of silicone rubber, while zinc oxide (ZnO) varistor elements provide the core overvoltage protection function.
Which standard applies to this surge arrester?
The product specification identifies IEEE C62.11 as the applicable standard. Buyers can request the relevant technical and test documentation for project evaluation.
What mounting configuration does the arrester use?
The upper terminal has four M12 threaded connection points with 1.75 in horizontal and vertical bolt spacing. The lower assembly uses a three-point mounting base.
Are mounting accessories available?
Mounting plates, NEMA brackets, and compatible connection accessories can be arranged according to the selected configuration and installation requirements.
Can you support OEM and bulk orders?
Yes. OEM production and bulk supply can be arranged according to approved technical specifications, drawings, mounting requirements, and order quantities.
Request a Quote for Metal Oxide Intermediate Class Surge Arresters
Send us your required rated voltage, MCOV, nominal discharge current, system grounding conditions, installation drawing, applicable standard, and order quantity.
Our team can review your technical requirements and provide the corresponding product configuration, technical documentation, and quotation for your purchasing project.
Hot Tags: metal oxide intermediate class surge arrester, China metal oxide intermediate class surge arrester manufacturers, suppliers, factory